+45 70 22 88 44 info@hss.dk

Auxiliary Control/Status Option

Auxiliary Control/Status Option
The AUXCS is an optional module for the TWS and Giant Voice® Siren System that allows the user to remotely control siren functions and to remotely collect siren status information via simple contact closures.

In addition to commands and status functions, the Auxiliary Control/Status Option has transformer coupled circuits for accepting audio. One circuit is active in conjunction with the Public Address command, while the other circuit is used for local audio, such as a local microphone or paging system. The local audio must have a “Push To Talk” contact closure
for operation. In either case the audio is broadcast over the system.

The following commands are supported:

Cancel (or Clear) Air Horn Silent Test
Wail Hi/Low Silent Test Clear
Attack Whoop Strobe On
Alert Noon Test Strobe Off
Public Address Digital Voice Messages (1 – 16)

The following status bits are supported with Normally Open relay Closures:

AC AC Voltage is present
DC DC Voltage level is good
Partial At least one amplifier is active
Full All amplifiers and drivers are active
Rotor Rotor Active
Intrusion Intrusion active